VCS/VMS Auxiliary Section Removal and Disassembly | Service Procedures TRSM0940
22. Remove the six cap screws that fasten the Output Shaft
bearing cover tot eh Auxiliary Section.
23. Remove
the Output Shaft bearing cover.
24. Inspect the Re
ar Bearing Cover oil seal for damage.
Remove if damage is found.
25. Remove
the rear portion of the tapered bearing which
should be free sitting in the race in the case. Also
remove the one piece race from it’s bore.