6. Place the Low Range Gear Assembly on its side. Drive
the pins through the lock washer using a punch and
hammer.
Note: Make sure pins
are installed below coupler thrust
surface.
7. Position the Low
Range Gear (Reduction Gear) on the
Output Shaft with the coupler facing forward on the
shaft.
8. Install the dowel
pin on the shaft
9. Position retainer w
asher on the front of the shaft.
10. Inst
all retainer nut on the front of the shaft. If reusing
nut, apply locking compound to the threads. New nuts
should have a pre-applied locking compound. Torque
to 180-210 lb-ft.