417101774_EMP_KKS_E60_E.doc - 17 - Rev. 8-03.10
7.2.3 Connector assignment of slot II (5-terminal)
input for pulse signal, standard signal, metering lock, batch and
metering monitoring
Fig. 7.11
2
5
1
4
3
1: output 5 V (loadable with max. 50 mA)
2: pulse input
(also as configurable batch / metering monitoring; see 10.3.13 & 10.3.15)
3: metering lock
(also as configurable batch / metering monitoring, see 10.3.13 & 10.3.15)
4: GND (
)
5: input 0/4...20 mA (contact 5 / 4)
(plug assignments: see also chapter 14.5.2 “Technical Specifications“)
# Remove the protective cap
# Mount the connector plug according to the connector assignment.
WARNING
Only use a connector plug from our product range! (included in the delivery scope)
7.2.3.1 Installing the pulse control (water meter)