417101774_EMP_KKS_E60_E.doc - 30 - Rev. 8-03.10
9.4.1 Software version display
Fig. 9.6
The current software version is displayed in the
top right of the main menu screen (Fig. 9.6).
Lowercase letters after the software number
(Fig. 9.6) describe internal software
modifications that do not affect the operation of
the device.
Fig. 9.7
If a dongle box or a MicroFlow
PLUS
has been
connected, the unit version (Fig 9.7) is displayed
to the right of the pump version.
9.4.2 Display at operating display
On delivery, the following basic factory settings appear on the display when the main
voltage is switch on.
Fig. 9.8
Operating mode: internal
Metering frequency / - quantity: strokes/min
(122 strokes/min at 50 Hz,
146 strokes/min at 60 Hz)
Operating state: OFF (in V 4.1, „Standby“ in V4.0
(to start the pump press
START / STOP key)
NOTE
With each stroke of the pump, the indicator in the upper right of the display rotates
1 turn.
9.4.3 Configuration
The following factory settings are defined in the configuration.
Fig. 9.9
Configuration of Standard Chapter
language: German see 10.3.3
unit: liter see 10.3.4
code: not active (-) see 10.3.5
auto start: not active (-) see 10.3.6
metering lock: not active (-) see 10.3.7
low level contact: open () see 10.3.8
alarm output: off (z) see 10.3.9
pulse memory: not active (-) see 10.3.10
oval gear meter: not active (-) see 10.3.11
metering controler: not active (-) see 10.3.12
meter monitor: not active (-) see 10.3.13
microflow : not active (-) see 10.3.14
batch: not active (-) see 10.3.15
degas: not active (-) see 10.3.16
microflow Only appears on the display in conjunction with the
MicroFlow
PLUS
metering monitor, which is available as an
accessory.