417101774_EMP_KKS_E60_E.doc - 56 - Rev. 8-03.10
10.4.3.2 Calibration / Start
Fig. 10.57
to : The pump runs 122 strokes (ca. 1 min).
The strokes are counted down from 122 to 0.
The oval gear meter pulses (OGM pulses) are counted upwards from 0.
NOTE
By activating the 'Menu/Exit’ function, the running calibration can be interrupted.
If the OGM pulses are not displayed, check all the connections to the pump!
to : After the running process, the amount removed from the measuring cylinder (see
chapter 10.4.3.1
“Preparation”) must be read off.
This quantity is then entered as the calibration value (in ml or l).
Fig. 10.58
During the calibration process, the oval gear pulses
determined appear on the display.