417101774_EMP_KKS_E60_E.doc - 39 - Rev. 8-03.10
10.3.5.2 Setting
Fig. 10.19
10.3.6 Configuration / Autostart
This funct
ion determines whether the pump is set to ‘OFF’ (‘Standby‘ in V 4.0) when the
mains connection is re-established following a power cut or if the pump should immediately
recommence functioning in the configured operation mode.
10.3.6.1 Selecting
Fig. 10.20
- autostart ist inactive.
When the mains voltage is connected,
the pump always enters the "OFF"
(“Standby“ in V 4.0) operating state.
(Default setting)
9 autostart ist active.
When the mains voltage is connected,
the pump starts functioning in the
configured operation state.
10.3.7 Configuration / Metering lock
If the metering lock is enabled, the pump only functions if an external enable contact is
connected to plug II between PINS 3+4 (see chapter 8.2.2.2
) (regardless of which operation
mode is set).