417101774_EMP_KKS_E60_E.doc - 47 - Rev. 8-03.10
10.3.13.6 Oval gear meter pulse display (only E60
PLUS
)
This display shows the number of pulses recorded during the last calibration process
(running time during calibration = 1 min).
If the value shown is less than 60, metering monitoring using an oval gear meter is only
possible to a limited extent.
Fig. 10.38
10.3.14 Configuration / MicroFlow
PLUS
NOTE
If the “MicroFlow
PLUS”
metering monitoring unit (product no. 248611) is connected to plug II
of the pump and the Plug & Play function is activated through the temporary removal of
the supply voltage or the pump being switched off and back on again, the
configuration/meter monitoring menu item is automatically replaced by the
configuration/MicroFlow menu item.
When installing/commissioning the MicroFlow
PLUS
metering monitoring system, please
consult the operating manual, product no. 417101314.
This function makes it possible to use a metering monitoring system with which a metering
pulse is emitted and evaluated on every pump stroke.
10.3.14.1 Selecting
- MicroFlow
PLUS
is inactive.
(Default setting)
9 MicroFlow
PLUS
is active.
Fig. 10.39
On activating MicroFlow
PLUS
, a
submenu appears with the
following menu items:
Menu item Chapter
• Stop pump 10.3.14.2
• Strokes 10.3.14.3
• Deviation 10.3.14.4
• Metering break 10.3.14.5
• Metering delay 10.3.14.6
• Calibration 10.3.14.7