417101774_EMP_KKS_E60_E.doc - 72 - Rev. 8-03.10
14.3.3 In-/ and output circuit
14.3.3.1 Connector I
input allocation external circuit declaration of value
empty report 1 + 4
Fig. 14.2
reserve 3 + 4
voltage-free contact
Note:
do not connect
any external voltages!
14.3.3.2 Connector II
input allocation external circuit declaration of value
pulse 2 + 4 minimum power-on and power-off time
15ms
metering lock/ batch/
metering monitoring
3 + 4
voltage-free contact
Note:
do not connect
any external voltages!
standard signal 4 + 5 external current
Note:
Observe the
polarity of the
connected signal!
0/4-20 mA, load approx. 50 ohms
output allocation external circuit declaration of value
Fig. 14.3
external
power supply
1 + 4 voltage-free contact
Note:
do not connect
any external voltages!
Power supply for ext. devices
Outputs: 5VDC; max. 50mA
14.3.3.3 Connector III
output allocation external circuit declaration of value
stroke signal 3 + 4 external current
Note: Observe the
polarity of the
connected signal!
max. external voltage 24 V DC,
max 0,3 A
when stationary: Contact open
at 50 Hz mains power:
at 100 % run:
contact approx. 310 ms closed
contact approx. 180 ms opened
at 50 % run:
contact approx. 310 ms closed
contact approx. 660 ms opened
at 60 Hz mains power:
at 100 % run:
contact approx. 260 ms closed
contact approx. 150 ms opened
at 50 % run:
contact approx. 260 ms closed
contact approx. 550 ms opened
Fig. 14.4
empty/reserve/fault
report
1 + 2 external current
max. external voltage 230 VAC/DC
max. 3 A
with reserve report:
contact approx. 500 ms closed
contact approx. 500 ms opened