10.3.13.4 Metering monitoring / Deviation (only at E60
PLUS
& OGM or OGM
PLUS
)
A tolerance in % is set under “deviation”.
The actual incoming pulse rate recorded by the oval gear meter within the pump interval to
be monitored (see chapter 10.3.13.3
configuration/strokes) is compared with the target
pulse rate defined during calibration.
If this comparison results in a deviation that is greater than the % value configured under
“deviation”, a “metering monitoring alarm” is triggered.
)
NOTE
This function can only be selected if a dongle box is connected and configuration/oval
gear meter (see chapter 10.3.11) has been activated.
Setting range: 0-100%
Fig. 10.36
Default setting = 20 %
10.3.13.5 Metering monitoring / Input (only at E60 WITHOUT Dongle box)
The “Input” setting is used to determine which input (pulse input or metering lock) at plug II
of the pump should be used to evaluate the incoming pulses from the metering monitoring
unit.
The flow monitor connection depends on the selected input:
Input pulse: = plug II Pin 2+4
Input metering lock: = plug II Pin 3+4
See chapter 7.2.3.5
.
)
NOTE
This function can only be selected if no dongle box is connected.
In this case, the original function (e.g. pulse input) can no longer be used.
Fig. 10.37