417101774_EMP_KKS_E60_E.doc - 23 - Rev. 8-03.10
8 Upgrading the EMP KKS E60 to the EMP KKS E60
PLUS
To upgrade the EMP KKS E60 to the EMP KKS E60
PLUS
and thus access the additional
functions, obtain the dongle box from our range of accessories. (Part No. 248606).
8.1 Fitting the dongle box
Pos. Description
V
input for oval gear meter
VI
Fixed connector cable for connecting the pulse input to the
EMP pump (input II)
1
Connection wire for connection to input II of the pump
2
Dongle box
VII
input for batch pulse and metering lock
Fig. 8.1
VIII
input for pulse, standard signal input and metering lock
Fig. 8.2
A
1
Fig. 8.3
2
Fit the dongle box (Fig. 8.1) to the rail of the EMP pump provided for this purpose
(Fig. 8.2, pos. A):
# Slide the dongle box (Fig. 8.1) onto the rail on the left side of the EMP pump
(Fig. 8.2, pos A), until it snaps into place.
# Connect the connection cable (Fig. 8.1, pos. 3 and 8.3, pos. 2) to the input for pulse /
standard signal (Fig. 8.2, pos 1).
# Switch the pump off and afresh on.
The additional functions in the metering pump electronics can thus be activated and executed.
)
NOTE
If, before upgrading with a dongle box, a plug is connected to the input for pulse / standard
signal (see Fig. 8.2, pos. 1), then this plug can be connected after the upgrade to plug VIII
(see Fig. 8.1, pos. VIII) of the dongle box.