417101774_EMP_KKS_E60_E.doc - 40 - Rev. 8-03.10
10.3.7.1 Selecting
Fig. 10.21
- interrogation of the metering lock
is inactive. (Default setting)
9 interrogation of the metering lock
is active.
10.3.8 Configuration / Low-level contact
This funct
ion specifies whether an open or a closed contact at the level input (plug I, see
chapter 7.2.2.1
) is regarded as level OK.
10.3.8.1 Selecting
Fig. 10.22
= contact open:
level not OK (empty)
contact closed:
level OK (full)
(Default setting)
z = contact closed:
level not OK (empty)
contact open:
level OK (full)
10.3.9 Configuration / Alarm output
This option permits the inversion of the alarm output (alarm output relay has pulled in or not
pulled in when the alarm was triggered).