417101774_EMP_KKS_E60_E.doc - 25 - Rev. 8-03.10
8.2.2 Connector assignments of Slot VII (5-terminal)
input for batch pulse and metering lock
Fig. 8.6
1: 5 V supply
2: Input for batch pulse
3: Input for metering lock
4: GND
5: Free for future use
# Remove the protective cap
# Mount the connector plug according to the connector assignment.
WARNING
Only use a connector plug from our product range!
8.2.2.1 Installing the batch pulse
)
HINWEIS
The batch funktion must be activated in menue first.
(see chapter: 10.3.15 batch configuration)
According to the requirements, the input of the batch pulse (contact 2+4 or contact 3+4)
must be configured. (see chapter 10.3.15.)