417101774_EMP_KKS_E60_E.doc - 71 - Rev. 8-03.10
14.3 Technical specifications "Overview tables"
14.3.1 General data
Pump type
Description
00002 00005 00009 00014
Supply voltage 230 V / 50/60 Hz *** ± 10 %
(special voltages on request)
max. power consumption I
N
115V 50/60 Hz
230V 50/60 Hz
0,2 A / 0,21 A
0,09 A
Motor power 115V 50/60 Hz
230V 50/60 Hz
18,7 / 19,8 W
Fuse rating 315 mA
Type of protection IP 65
Breaking capacity at circuit with 24 V
Empty report output
stroke signal output
24 V 3 A AC/DC
24 V 0,3 A DC
Breaking capacity at circuit with 230 V
Empty report output
stroke signal output
230 V / 3 A AC/DC
connection according to VDE is not permitted
14.3.2 General data - Standard pumps
Pump type
Description
00002 00005 00009 00014
Pump output [l/h]* 0,2 0,5 0,9 1,4
Max. metering backpressure [bar] 10
Piston diameter [mm] 3 4,76 6,34 8
Number of strokes [1/min] at 50 Hz 122
Metering quantity/stroke [cm³] 50 Hz/60 Hz 0,027/0,032 0,068/0,082 0,12/0,44 0,19/0,23
Metering accuracy [see chapter 14.6] < ± 3%
Max. conveyable viscosity [mPas] 200
Permitted ambient temperature 5-40°C
Suction height [mWs] at 100 % stroke** 2
Max. pre-pressure (suction side) [bar] 0,3
Hose connectors
Suction-/Returnline [ID mm]
6/8, 6/10, 6/12
Hose connectors
Pressure(metering)line [ID mm]
2/4 4/6
Weight [kg] 2,4
* all data relate to water at 20 °C
** Suction heights with clean, moistened valves at 100% metering stroke and max. stroke frequency
*** At a mains power frequency of 60 Hz, the delivery capacity increases by 20%, while the metering backpressure decreases