EasyManua.ls Logo

Edwards SCU-800 - Page 86

Edwards SCU-800
141 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SCU-800 Control Unit for Turbomolecular Pump
MT-49E-101-G
Page 74
5
SERIAL COMMUNICATION
PROTOCOL
Transmission frame when data is transmitted to two blocks (message is more than 256 characters
and less than 512 characters):
Designate the control command (the 1st block) on the PC.
PC->SIM
@
F
1
F
2
Stx
0
0
1
Sp
CHR
C
1
C
253
Etb
LRC
SIM->PC
Ack or Nak
F
1
F
2
Next, the preceding SIM->PC character is "Ack", the PC continues instructing the control command
(the 2nd block).
PC->SIM
@
F
1
F
2
Stx
0
0
2
C
254
C
n
Etx
LRC
SIM->PC
Ack or Nak
F
1
F
2
Always assign less than 510 characters (n< 510) to the parameter so that the message is less than
512 characters.
Then the preceding SIM->PC character is "Ack", the instructed control command is executed and the
SIM returns the following response.
PC->SIM
Ack or Nak
F
1
F
2
SIM->PC
@
F
1
F
2
Stx
0
0
1
# or !
Etx
LRC
The PC transmits "Ack" or "Nak"; then transmits the next command if necessary.