280 E300 Design Guide
Issue Number: 1
See T5 T6 Analog Input 1 Scaling (F35).
See T5 T6 Analog Input 1 Scaling (F35).
See T5 T6 Analog Input 1 Mode (F38).
The scaling, offset and invert functions for analog input 3 are defined in the same way as for analog input 1. See T5 T6 Analog Input 1 Scaling (F39).
The scaling, offset and invert functions for analog input 3 are defined in the same way as for analog input 1. See T5 T6 Analog Input 1 Scaling (F39).
F50 T7 Analog Input 2 Minimum
Mode Open-Loop, RFC-A, RFC-S
Minimum -100.00 Maximum 100.00
Default -100.00 Units %
Type 16 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 2
Coding RW
F51 T7 Analog Input 2 Maximum
Mode Open-Loop, RFC-A, RFC-S
Minimum -100.00 Maximum 100.00
Default 100.00 Units %
Type 16 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 2
Coding RW
F52 T8 Analog Input 3 Mode
Mode Open-Loop, RFC-A, RFC-S
Minimum 6 Maximum 9
Default 6 Units
Type 16 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, TE
Value Text
6 Volt Input
7 Therm Short Cct
8Thermistor
9 Thermistor Input
F53 T8 Analog Input 3 Scaling
Mode Open-Loop, RFC-A, RFC-S
Minimum 0.000 Maximum 10.000
Default 1.000 Units
Type 16 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 2
Coding RW
F54 T8 Analog Input 3 Invert
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default 0 Units
Type 16 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW