Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
User Menu A Commissioning
Advanced
Parameters
Diagnostics Optimization CT MODBUS RTU Technical Data
372 E300 Design Guide
Issue Number: 1
Mode: Open-Loop, RFC-A, RFC-S
Logic Function 1 Output (K01) shows the output of logic function 1.
Logic Function 1 Source 1 (K02) defines input source 1 of logic function 1.
Setting Logic Function 1 Source 1 Invert (K03) inverts input 1 of logic function 1.
Logic Function 1 Source 2 (K04) defines input source 2 of logic function 1.
Setting Logic Function 1 Source 2 Invert (K05) inverts input 2 of logic function 1.
RW Read / Write RO Read-only Bit Bit parameter Txt Text string Date Date parameter Time Time parameter
Chr
Character
parameter
Bin Binary parameter IP IP address Mac MAC address Ver Version number SMP
Slot, menu,
parameter
Num Number parameter DE Destination ND No default value RA Rating dependent NC Non-copyable PT Protected
FI Filtered US User save PS Power-down save
K01 Logic Function 1 Output
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default Units
Type 1 Bit Volatile Update Rate 4 ms write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
K02 Logic Function 1 Source 1
Mode Open-Loop, RFC-A, RFC-S
Minimum A00 Maximum AB99
Default A00 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Menu Param Alpha Numeric Decimal Places 3
Coding RW, PT, BU
K03 Logic Function 1 Source 1
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default 0 Units
Type 1 Bit User Save Update Rate 4 ms read
Display Format Standard Decimal Places 0
Coding RW
K04 Logic Function 1 Source 2
Mode Open-Loop, RFC-A, RFC-S
Minimum A00 Maximum AB99
Default A00 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Menu Param Alpha Numeric Decimal Places 3
Coding RW, PT, BU
K05 Logic Function 1 Source 2 Invert
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default 0 Units
Type 1 Bit User Save Update Rate 4 ms read
Display Format Standard Decimal Places 0
Coding RW