E300 Design Guide 397
Issue Number: 1
See Trip 0 (L29).
See Trip 0 (L29).
See Trip 0 (L29).
See Trip 0 (L29).
When set to On (1), the drive trip log is reset. This parameter will automatically reset to Off (0) when the trip log reset has completed.
This parameter is intended for service personnel to reset the trip log manually as part of routine maintenance.
L35 Trip 6
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 255
Default Units
Type 8 Bit Power Down Save Update Rate Write on trip
Display Format Standard Decimal Places 0
Coding RO, TE, ND, NC, PT, BU
L36 Trip 7
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 255
Default Units
Type 8 Bit Power Down Save Update Rate Write on trip
Display Format Standard Decimal Places 0
Coding RO, TE, ND, NC, PT, BU
L37 Trip 8
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 255
Default Units
Type 8 Bit Power Down Save Update Rate Write on trip
Display Format Standard Decimal Places 0
Coding RO, TE, ND, NC, PT, BU
L38 Trip 9
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 255
Default Units
Type 8 Bit Power Down Save Update Rate Write on trip
Display Format Standard Decimal Places 0
Coding RO, TE, ND, NC, PT, BU
L39 Reset Trip Log
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default Units
Type 1 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, ND, NC