E300 Design Guide 429
Issue Number: 1
See Data Logger Trace 1 Source (Y02).
See Data Logger Trace 1 Source (Y02).
The scope is triggered by a rising edge at the input to the main scope block. If Data Logger Trigger Source (Y07) is set at its default value of 0.000
then the output of the trigger threshold comparator is 0, and so the scope can be triggered with Data Logger Trigger (Y06). Data Logger Trigger Invert
(Y09) can be used to invert the trigger signal.
If Data Logger Trigger (Y06) = 0, the scope can be triggered based on the level of a parameter defined by Data Logger Trigger Source (Y07) and the
Data Logger Trigger Threshold (Y08). This source operates in the same way as the trace sources and a direct comparison is made between the
actual parameter value and the threshold. Decimal places are ignored. The threshold detector output is 1 when the value from the scope trigger
source is greater than Data Logger Trigger Threshold (Y08). If Data Logger Trigger Source (Y07) = 0.000, or it is used to select a parameter that does
not exist or is non-visible, then the output of the threshold detector is 0.
See Data Logger Trigger Source (Y07).
Y04 Data Logger Trace 3 Source
Mode Open-Loop, RFC-A, RFC-S
Minimum A00 Maximum AB99
Default A00 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Menu Param Alpha Numeric Decimal Places 3
Coding RW, PT, BU
Y05 Data Logger Trace 4 Source
Mode Open-Loop, RFC-A, RFC-S
Minimum A00 Maximum AB99
Default A00 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Menu Param Alpha Numeric Decimal Places 3
Coding RW, PT, BU
Y06 Data Logger Trigger
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default 0 Units
Type 1 Bit Volatile Update Rate 250 μs read
Display Format Standard Decimal Places 0
Coding RW
Y07 Data Logger Trigger Source
Mode Open-Loop, RFC-A, RFC-S
Minimum A00 Maximum AB99
Default A00 Units
Type 16 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, PT, BU
Y08 Data Logger Trigger Threshold
Mode Open-Loop, RFC-A, RFC-S
Minimum -2147483648 Maximum 2147483647
Default 0 Units
Type 32 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW