Emerson Process Management GmbH & Co. OHG9-36
X-STREAM XE
Instruction Manual
HASXEE-IM-HS
10/2012
9.4 List of Parameters and Registers - Sorted by Daniel Registers
Address Tag Name
Data
Type
Client
Access
Description
Daniel Modicon
2067 2067 Control.ApplyGas.Span3Valve2 Boolean R/W 0=open sample valve; 1=open span3 valve comp2
2068 2068 Control.ApplyGas.Span4Valve2 Boolean R/W 0=open sample valve; 1=open span4 valve comp2
2069 2069 Control.ApplyGas.Span1Valve3 Boolean R/W 0=open sample valve; 1=open span1 valve comp3
2070 2070 Control.ApplyGas.Span2Valve3 Boolean R/W 0=open sample valve; 1=open span2 valve comp3
2071 2071 Control.ApplyGas.Span3Valve3 Boolean R/W 0=open sample valve; 1=open span3 valve comp3
2072 2072 Control.ApplyGas.Span4Valve3 Boolean R/W 0=open sample valve; 1=open span4 valve comp3
2073 2073 Control.ApplyGas.Span1Valve4 Boolean R/W 0=open sample valve; 1=open span1 valve comp4
2074 2074 Control.ApplyGas.Span2Valve4 Boolean R/W 0=open sample valve; 1=open span2 valve comp4
2075 2075 Control.ApplyGas.Span3Valve4 Boolean R/W 0=open sample valve; 1=open span3 valve comp4
2076 2076 Control.ApplyGas.Span4Valve4 Boolean R/W 0=open sample valve; 1=open span4 valve comp4
2077 2077 Control.ApplyGas.Span1Valve5 Boolean R/W 0=open sample valve; 1=open span1 valve comp5
2078 2078 Control.ApplyGas.Span2Valve5 Boolean R/W 0=open sample valve; 1=open span2 valve comp5
2079 2079 Control.ApplyGas.Span3Valve5 Boolean R/W 0=open sample valve; 1=open span3 valve comp5
2080 2080 Control.ApplyGas.Span4Valve5 Boolean R/W 0=open sample valve; 1=open span4 valve comp5
2081 2081 Control.ApplyGas.PumpState1 Boolean R/W Pump1 state (0=Off 1=On)
2082 2082 Control.ApplyGas.PumpState2 Boolean R/W Pump1 state (0=Off 1=On)
2091 2091 Control.Acknowledge.AllStates Boolean R/W 1=Acknowledge device's states; 0=no effect
2092 2092 Control.Acknowledge.Failure Boolean R/W
1=Acknowledge device's Namur Failure alarms;
0=no effect
2093 2093 Control.Acknowledge.OffSpecs Boolean R/W
1=Acknowledge device's Namur Off-spec alarms;
0=no effect
2094 2094
Control.Acknowledge.MaintRe-
quests
Boolean R/W
1=Acknowledge device's Namur MaintRequ
alarms; 0=no effect
2095 2095 Control.Acknowledge.FctChecks Boolean R/W
1=Acknowledge device's Namur FctCheck alarms;
0=no effect
2096 2096 Control.Acknowledge.LevelAlarms Boolean R/W 1=Acknowledge device's level alarms; 0=no effect
3001 3001 Service.General.ChannelActive1 Word R/W built-in component1
3002 3002 Service.General.ChannelActive2 Word R/W built-in component2
3003 3003 Service.General.ChannelActive3 Word R/W built-in component3
3004 3004 Service.General.ChannelActive4 Word R/W built-in component4
3005 3005 Service.General.ChannelActive5 Word R/W built-in component5
3010 3010 Setup.Display.Language Word R/W Language (0=EN 1=DE 2=FR ...)
3011 3011
Setup.Display.Component.PV_
Unit1
Word R/W PV1 unit: 0 = Custom, ppm, ppb, Vol%
3016 3016
Setup.Display.Component.PV_
Unit2
Word R/W PV2 unit: 0 = Custom, ppm, ppb, Vol%
3021 3021
Setup.Display.Component.PV_
Unit3
Word R/W PV3 unit: 0 = Custom, ppm, ppb, Vol%
3026 3026
Setup.Display.Component.PV_
Unit4
Word R/W PV4 unit: 0 = Custom, ppm, ppb, Vol%
3031 3031
Setup.Display.Component.PV_
Unit5
Word R/W PV5 unit: 0 = Custom, ppm, ppb, Vol%
3036 3036
Setup.Display.Component.Preci-
sion1
Word R/W decimal points displayed for component1