Emotron AB 01-3694-01r2 Technical Data 157
14. Technical Data
14.1 Electrical specifications
related to model
Table 34 Typical motor power at mains voltage 400 V
Model
Max. output
current for 60 s
[Arms]
Normal duty (120%) Heavy duty (150%)
Frame size
Power @400V
[kW]
Rated current
[Arms]
Power @400V
[kW]
Rated current
[Arms]
FDU40-003 3.0 0.75 2.5 0.55 2
X1
FDU40-004 4.8 1.5 4 1.1 3.2
FDU40-006 7.2 2.2 6 1.5 4.8
FDU40-008 9.0 3 7.5 2.2 6
FDU40-010 11.4 4 9.5 3 7.6
FDU40-013 15.6 5.5 13 4 10.4
FDU40-018 22 7.5 18 5.5 14.4
S2
FDU40-026 31 11 26 7.5 21
FDU40-031 37 15 31 11 25
FDU40-037 44 18.5 37 15 29.60
FDU40-046 55 22 46 18.5 37
X2FDU40-060 73 30 61 22 49
FDU40-073 89 37 74 30 59
FDU48-090 108 45 90 37 72
E
FDU48-109 131 55 109 45 87
FDU48-146 175 75 146 55 117
FDU48-175 210 90 175 75 140
FDU48-210 252 110 210 90 168
F
FDU48-250 300 132 250 110 200
FDU48-300 360 160 300 132 240
G
FDU48-375 450 200 375 160 300
FDU48-430 516 250 430 200 344
H
FDU48-500 600 250 500 250 400
FDU48-600 720 315 600 250 480
IFDU48-650 780 355 650 315 520
FDU48-750 900 400 750 355 600
FDU48-860 1032 450 860 400 688
J
FDU48-1000 1200 500 1000 450 800
FDU48-1200 1440 630 1200 500 960
K
FDU48-1500 1800 800 1500 630 1200