Proline Promass 83 PROFIBUS DP/PA Commissioning
Endress+Hauser 85
5. Configuration of totalizers 1-3:
Promass 83 has 3 totalizers. The following example applies to totalizer 1.
In the “CHANNEL” parameter, select the measured variable (e.g. mass flow) to be
transmitted to the PROFIBUS master as the totalizer value 1:
BASIC FUNCTION (G) PROFIBUS PA (GCA) TOTALIZER (613)...
... SELECT TOTALIZER (6130) Select: TOTALIZER 1
... CHANNEL (6133) Select: MASS FLOW
or enter the ID: 277
Possible settings: see following table.
Enter the desired totalizer units:
BASIC FUNCTION (G) PROFIBUS DP/PA (GBA) TOTALIZER (613)
UNIT TOTALIZER (6134)
Configure totalizer status, e.g. totalise:
BASIC FUNCTION (G) PROFIBUS DP/PA (GBA) TOTALIZER (613)
SET TOTALIZER (6135) Select: TOTALISE
Set the totalizer mode, e.g. for balancing:
BASIC FUNCTION (G) PROFIBUS DP/PA (GBA) TOTALIZER (613)
TOTALIZER MODE (6137) Select: BALANCE
The following settings are possible:
6. Select the operating mode (GSD file) which should be used for cyclic communication with the
PROFIBUS master.
BASIC FUNCTION (G) PROFIBUS PA (GCA) OPERATION (614)
SELECTION GSD (6140) Select:
MANUFACT. SPEC. (factory setting): Promass 83 measuring device is operated in the
manufacturer-specific mode.
MANUFACT V2.0: Promass 83 is used as the replacement for the previous Promass 63
model (compatibility mode).
GSD PROFILE: Promass 83 is operated in the Profile mode.
!
Note!
For PROFIBUS network configuration, make sure that the right device master file (GSD file) of
the measuring device is used for the selected operating mode:
!
Note!
Further information on the device master file Page 86
7. Configuration of cyclic data communication in the PROFIBUS master:
A detailed description of the system integration can be found on Page 86.
Measured variable ID for “CHANNEL” parameter
Mass flow (factory setting totalizers 1...3) 277
Volume flow 273
Corrected volume flow 398
Operating mode Device master file (GSD-file)
MANUFACT. SPEC. “eh3x152A.GSD” or “eh3_152A.GSD” (depends on the PROFIBUS master used)
MANUFACT V2.0 “eh3x1506.GSD” or “eh3_1506.GSD” (depends on the PROFIBUS master used)
GSD PROFILE “PA139742.GSD”