AcuLaser C2800/C2800D/C3800/C3800D Revision C
TROUBLESHOOTING Engine-related Trouble FIP 105
Confidential
FIP 1-26 Service Req E500 (Motor Failure)
Possible parts that caused the error
Troubleshooting
DRIVE ASSY MAIN
DRIVE ASSY PH
HARNESS ASSY R SIDE
PWBA MCU
Step Check Yes No
1
Check after turning the power OFF and ON.
Does the error recur even when the power is
turned off and back on again?
Go to Step [2]. End of procedure
2
Check the operation of the Main Motor in
the DRIVE ASSY MAIN
Check the Main Motor with reference to FIP 2-7
(p.124). Was the trouble fixed?
End of procedure Go to Step [3].
3
Check the operation of the Sub Motor in the
DRIVE ASSY MAIN
Check the Sub Motor with reference to FIP 2-8
(p.124). Was the trouble fixed?
End of procedure Go to Step [4].
4
Check the operation of the Deve Motor in the
DRIVE ASSY MAIN
Check the Deve Motor with reference to FIP 2-9
(p.125). Was the trouble fixed?
End of procedure Go to Step [5].
5
Check the operation of the DRIVE ASSY PH
Check the DRIVE ASSY PH with reference to
FIP 2-6 (p.123).
--- ---