AcuLaser C2800/C2800D/C3800/C3800D Revision C
TROUBLESHOOTING      Engine-related Trouble FIP 123
Confidential
FIP 2-5  CLUTCH ASSY PH REGI
 Possible parts that caused the error
 Troubleshooting
FIP 2-6  DRIVE ASSY PH
 Possible parts that caused the error
 Troubleshooting
 CLUTCH ASSY PH REGI
 HARNESS ASSY R SIDE
 PWBA MCU
Step Check Yes No
1
Check the connection of the CLUTCH ASSY 
PH REGI
Check the connection state between CLUTCH 
ASSY PH REGI and PWBA MCU. 
Are P/J23 and P/J233 connected correctly?
Go to Step [2]. Reconnect P/J23 
and P/J233 
correctly.
2
Check the continuity of the HARNESS ASSY 
R SIDE
Is the continuity between P/J23 <=> P/J233 
normal
?
Go to Step [3]. Replace the 
HARNESS 
ASSY R SIDE.
3
Check the power voltage supply to CLUTCH 
ASSY PH REGI
1. Close the interlock switch (HARNESS 
ASSY INTERLOCK) before performing 
the following work.
2. Measure the voltage between PWBA 
MCU ground <=> P/J23-11PIN.
Is the power voltage (approx. +24 V) output? 
Replace the 
CLUTCH ASSY 
PH REGI. 
(p.226)
Replace the 
PWBA MCU. 
(p.343)
 DRIVE ASSY PH
 HARNESS ASSY R SIDE
 PWBA MCU
Step Check Yes No
1
Check the connection of the DRIVE ASSY 
PH
Check the connection state between DRIVE 
ASSY PH and PWBA MCU. 
Are P/J25 and P/J251 connected correctly?
Go to Step [2]. Reconnect P/J25 
and P/J251 
correctly.
2
Check the continuity of the HARNESS ASSY 
R SIDE
Is the continuity between P/J25 <=> P/J251 
normal
?
Go to Step [3]. Replace the 
HARNESS 
ASSY R SIDE.
3
Check the power voltage supply to DRIVE 
ASSY PH
1. Close the interlock switch (HARNESS 
ASSY INTERLOCK) before performing 
the following work.
2. Measure the voltage between PWBA 
MCU ground <=> P/J25-1PIN, P/J25-
2PIN.
Is the power voltage (approx. +24 V) output?
Replace the 
DRIVE ASSY 
PH. 
(p.317)
Replace the 
PWBA MCU. 
(p.343)