AcuLaser C2800/C2800D/C3800/C3800D Revision C
TROUBLESHOOTING Print Quality Trouble FIP 148
Confidential
FIP-P12 THE PRINTED IMAGE IS SKEWED
Before starting troubleshooting, inspect the paper feed path of the printer paper. Check
the paper feed path for metal staples, paper clips, paper scraps, and other foreign
matter.
Symptom / Possible Parts
Symptom
Printed image is skewed.
Possible Parts
TRANSFER UNIT
ROLL ASSY RETARD
ROLL ASSY FEED MSI
ROLL ASSY TURN
ROLL ASSY FEED (Feed Roll/Nudger Roll)
ROLL ASSY FEED (Retard Roll)
ROLL ASSY FEED (OPT)/(Feed Roll/Nudger Roll)
ROLL ASSY FEED (OPT)/(Retard Roll)
ROLL REGI METAL
ROLL REGI RUBBER
ROLL ASSY DUP-1
ROLL ASSY DUP-2
Step Check Yes No
1
Check the paper
Is it a new standard paper free from moisture?
Go to Step [2]. Replace it with a
new standard
paper free from
moisture.
2
Installation state of the paper cassette and
papers
Reload the papers against the paper guide, and
run test print. Are images printed normally?
End of procedure Go to Step [3].
3
Check the Paper Feed Rollers
1. Are the rollers on the paper feed path not
soiled, damaged or worn?
2. Are those rollers installed correctly?
Go to Step [4]. Clean the roll or
replace it.
4
Check the installation of the TRANSFER
UNIT
Reinstall the TRANSFER UNIT and make a
test print. Are images printed normally?
End of procedure Replace the
TRANSFER
UNIT. (p.268)
Step Check Yes No