PROCEDURE
1) Locate the part you want to remove in the table.
2) Check the guide of the part.
For example: If you want to remove the ROS ASSY, the guide is “B”.
3) Go to main pages, find the column(s) that has the foregoing guide on the
upper left corner, and perform the operation described in the column(s).
For example: To remove the ROS ASSY, you need to remove all the parts
or components that have “B” on the upper left column in
ascending page order.
4) Remove the objective part.
4.4.13 XEROGRAPHICS (PART 2)
DISASSEMBLED PARTS
Table 4-13. List of Disassembled Parts
Name Guide
SENSOR ASSY CRU (K)
CONNECTOR CRUM
ROS ASSY
HVPS
HOUSING ASSY B
SENSOR PHOTO:TONER CARTRIDGE
A
B
C
D
Locate the part and
find its guide.
COVER ASSY FRONT
A
B
C
D
LATCH
COVER ASSY FRONT
Perform the operation in
the column with “B” on
the corner.
AcuLaser C2800/C2800D/C3800/C3800D Revision A
DISASSEMBLY/ASSEMBLY DISASSEMBLY/REASSEMBLY 276
5. Remove the six screws (silver, 6 mm) that secure the LVPS to the SHIELD LVPS.
6. Remove the LV PS from the SHIELD LVPS.
Kmy03066EA
5)
5)
5)
5)
5) 5)
6)
LVPS
ROS ASSY
1. Disconnect connector of the ROS ASSY (P/J12) on the PWBA MCU.
2. Remove the CORE TC-18-10-10 from the harness of the ROS ASSY, and pull out the connector
through the hole in the SHIELD MCU.