DISASSEMBLY/REASSEMBLY Disassembly/Reassembly 204
Confidential
Route the HARNESS ASSY FRONT COVER (black) under the HARNESS ASSY-CON
F (white) in the section indicated with A.
The part of the KIT COVER ASSY HARN SEC indicated with B should be placed
inside of the metal plate of the COVER ASSY FRONT.
8. Release the harness of the HARNESS ASSY FRONT COVER from the two tabs of the KIT COVER
ASSY HARN SEC.
Route the harness of the HARNESS ASSY FRONT COVER so that there is no slack.
9. Release the two tabs of the connector (P/J2720) that connect the HARNESS ASSY FRONT COVER
to the FEEDER ASSY DUP, and remove the HARNESS ASSY FRONT COVER from the KIT
COVER ASSY HARN SEC.
Kmy03091EA
8)
9)-1
9)-1
9)-2
8)
HARNESS ASSY FRONT COVER
HARNESS ASSY-CON F
Open and close the COVER ASSY FRONT to check if the harnesses routed through the
DUCT DRV PH are under no-load conditions.
1. Disconnect the connectors (P/J OP2, P/J OP3) of the HARNESS ASSY-CON F (main unit side).
2. Release the HARNESS ASSY-CON F from the DUCT DRV PH.
Make sure that the ground wire (green), HARNESS ASSY-CON F (white), and HARNESS
ASSY FRONT COVER (black), which are coming out of the COVER ASSY FRONT, are
routed as shown in figure-C.
NEXT>>
C
Kmy03092EA
Figure-C
HARNESS ASSY-CON F (White)
Gap
Gap
HARNESS ASSY FRONT
COVER (Black)
Ground Wire
(Green)
1)