Epson DFX 9000 Revision B
Disassembly and Assembly AC SW ASY, INLET ASY 142
4.2.3.4 AC SW ASY, INLET ASY
1. Remove the PR MECHA ASY (p. 149)
2. Release the AC SW ASY cables from the three cable routing tabs
and two cable clamps that secure the AC SW ASY cable to the
LOWER UNIT.
3. Disconnect the AC SW ASY connector (ACIN: 3 pins) from the
POWER UNIT.
4. Disconnect the AC SW ASY cables (blue and brown) from the
INLET ASY.
Figure 4-15. AC SW ASY Removal (1)
W A R N I N G
Disconnect the power cable and wait at least 5 minutes for
capacitors to drain before disassembling the POWER
UNIT. If you touch the POWER UNIT with the power
supplied, you may receive an electric shock.
Connect the AC SW ASY cable to the INLET ASY
correctly, as shown in Figure 4-15.
Upper pin: the blue cable.
Lower pin: the brown cable.
Cable
clamps
INLET ASY
INLET ASY
Tabs
Blue cable
Brown cable
AC SW ASY
7)
2)-1
Connector
(ACIN)
3)
2)-2
4)
POWER UNIT