5.
Edit and save this CSV
le
in a spreadsheet application such as
Microso
Excel or in a text editor.
c
Important:
When editing the
le,
do not change the encoding and header information.
CSV File Setting Items
Item Settings and Explanation
UserID Enter the user ID to use authentication between 1 and 83 bytes in Unicode.
UserName Enter the user name displayed on the scanner's control panel within 32 characters in
Unicode. You can leave this blank.
Password Enter the password to use for authentication within 32 characters in ASCII. When
importing, this is set as the password instead of EncPassword.
Leave this blank if you select User ID for How to Authenticate User.
When exporting, this is always blank.
AuthenticationCardID Set the reading result of Authenticate card. When you permit Allow users to register
authentication cards in Authentication Settings, the result registered by users is
reected.
Enter within 116 characters in ASCII. You can leave this blank.
IDNumber This item is displayed when Card or ID Number or ID Number is selected in
Authentication Settings > How to Authenticate User.
Enter a number that falls somewhere between the number set in Authentication
Settings > The Minimum Digit Number of ID Number and is up to 8 digits.
An ID Number cannot be duplicated. If it is duplicated, you will be alerted to the error
when importing the le. When left blank, it is automatically assigned a number.
Department Enter the department name arbitrary to distinguish the users.
Enter within 40 characters in Unicode. You can leave this blank.
MailAddress Set the email address for the users. This is used as the destination for Scan to My
Email.
You can use A-Z, a-z, 0-9, !#’%&’*+-./=?^_{|}~@. Enter 200 characters or less. You cannot
use “," (comma) for the rst character. You can leave this blank.
FolderProtocol Set the type of Scan to My Folder function.
Network Folder/FTP (SMB): 0, FTP: 1
FolderPath Set the saving destination for the Scan to My Folder function.
FolderUserName Set the user name for the Scan to My Folder function.
FolderPassword Set a password to authenticate the destination folder for the Scan to My Folder
function within 32 ASCII characters.
When importing, this is set as the password instead of EncPassword. When exporting,
this is always blank.
FtpPassive Set the connection mode for the FTP server when FTP is selected as the Type for the
Scan to My Folder function.
Active mode: 0, Passive mode: 1
Authentication Settings
>
Registering and Setting Information
>
Registering User Settings
134