2021
Stack area size exceeded.
Stack error.
Function call or local
variable is out of range.
If using many local variables, especially
String type, replace them to global
variables.
2022
Stack failure.
Required data not
found on the stack.
Rebuild the project.
2023
Stack failure.
Unexpected tag found
on the stack.
Rebuild the project.
2024
Stack area size exceeded. Local
variable is out of range.
Change the size of the Local variable.
2031
System failure.
Robot number is beyond the maximum
count.
Restore the controller configuration.
2032
System failure.
Task number compliance error.
Rebuild the project.
2033
System failure.
Too many errors.
Remedy the errors occurring frequently.
2040
Thread failure.
Failed to create the thread.
Reboot the controller.
2041
Thread failure.
Thread creation timeout.
Reboot the controller.
2042
Thread failure.
Thread termination timeout.
Reboot the controller.
2043
Thread failure.
Thread termination timeout.
Reboot the controller.
2044
Thread failure.
Daemon process timeout.
Reboot the controller.
2045
Thread failure.
Task continuance wait timeout.
Reboot the controller.
2046
Thread failure.
Task stop wait timeout.
Reboot the controller.
2047
Thread failure.
Task startup wait timeout.
Reboot the controller.
2050
Object file operation failure.
Object file size is beyond the allowable
size.
Rebuild the project.
2051
Object file operation failure.
Cannot delete the object file during
execution.
Reboot the controller.
2052
Object file operation failure.
Cannot allocate the memory for the
object file.
Reboot the controller.
2053
Object file update.
Updating the object file.
Perform the same
processing after a
while. Rebuild the project.
2054
Object file operation failure.
Function ID failure.
Rebuild the
project.
Synchronize the files of the project.
Rebuild the project.
2055
Object file operation failure.
Local variable ID failure. Rebuild
the project.
Synchronize the files of the project.
Rebuild the project.
2056
Object file operation failure.
Global variable ID failure. Rebuild
the project.
Synchronize the files of the project.
Rebuild the project.
RC90 (EPSON RC+ 7.0) Rev.4
129

Table of Contents

Other manuals for Epson RC90

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson RC90 and is the answer not in the manual?

Epson RC90 Specifications

General IconGeneral
BrandEpson
ModelRC90
CategoryController
LanguageEnglish

Related product manuals