Maintenance 9. Troubleshooting
No. Message Remedy Note 1 Note 2
3121 Corresponding Send cannot be found.
The number of Send statements is not
enough. Add the Send.
3122
Cannot specify the second parameter.
(Not in use)
3123
On/Off
statements are beyond the
maximum count.
An upper limit is set on the number of
On/Off statements. Check the upper
limit and correct the program.
3124
Point number is beyond the maximum
count.
An upper limit is set on the available
number of points.
Check the upper
limit and correct the program.
3125 Corresponding If cannot be found.
The number of EndIf statements is too
many. Delete the unnecessary EndIf.
3126 Corresponding Do cannot be found.
The number of Loop statements is too
many. Delete the unnecessary Loop.
3127 Corresponding Select cannot be found.
The number of Send statements is too
many. Delete the unnecessary Send.
3128 Corresponding For cannot be found.
The number of Next statements is too
many. Delete the unnecessary Next.
3129
'_' cannot be used as the first character
of an identifier.
Change the first character of the
identifier to an alphabetic character.
3130 Cannot specify Rot parameter.
3131 Cannot specify Ecp parameter.
3132 Cannot specify Arch parameter.
3133 Cannot specify LimZ parameter.
3134 Cannot specify Sense parameter.
3135 Invalid parameter is specified.
3136 Cannot use #include.
3137
Cannot specify the array variable
subscript.
The array variable subscript cannot be
specified.
3138
ByRef was not specified on Function
declaration.
3139
Cannot execute the Xqt statement for a
function that needs a ByRef parameter.
The Xqt statement cannot be executed
for a function needing a ByRef
parameter. Delete the ByRef
parameter.
3140
Cannot execute the Redim statement
for a ByRef variable.
3141 OBJ file is corrupt.
3142
OBJ file size is beyond the available
size after compiling.
The compilation result exceeds the limit
value. Divide the program.
3143
Ident length is beyond the available
size.
3144 ' ** ' already used for a function name.
3145
' ** ' already used for a Global
Preserve variable.
3146
' **
' already used for a Global
variable.
3147
' ** '
already used for a Module
variable.
3148 ' ** ' already used for a Local variable.
3149 ' ** ' already used for an I/O label.
RC90 (EPSON RC+ 7.0) Rev.4
148