EPSON Stylus Color 670 Revision A
Product Description Interface 15
1.3 Interface
1.3.1 Hardware interface
This printer provides USB and parallel interface as standard.
1.3.1.1 Parallel interface
o Transmission mode: 8-bit parallel, IEEE-1284 compatibility
mode
o Synchronization mode: By STROBE pulse
o Handshaking: By BUSY and ACKNLG signal
o Signal level: TTL compatible level
o Adaptable connector: 57-30360 (amphenol) or equivalent
BUSY signal is set high before setting either -ERROR low or PE high and
held high until all these signals return to their inactive state.
BUSY signal is at high level in the following cases.
-During data entry (see Figure 1-3, "Data Transmission Timing Chart")
-When input data buffer is full.
-When -INIT signal is at low level or during hardware initialization
-During printer error (see the ERROR signal explanation below)
-When the parallel interface is not selected
ERROR signal is at low level when the printer is in one of the following
states.
-Printer hardware error (fatal error)
-Paper-out error
-Paper-jam error
-Ink-out error
PE signal is at high level during paper-out error.
The figure below shows the timing chart of the parallel interface.
Figure 1-3. Data Transmission Timing Chart
On the above timing chart, T
act
rated period is shown below.
Table 1-3. t
act
Rated Period
Parallel I/F Mode T
act
Rated Period
High speed (default) 1
µs
Normal speed 3µs
Data byte n Data byte n+1DATA
/STROBE
BUSY
/ACKNLG
t
hold
t
setup
t
ready
t
stb
t
busy
t
reply
t
ack
t
nbusy
t
next
timechart