Disassembly and Assembly Removal of Exterior Parts 94
4.2.8 Valve Assy (Including Ink Tube Assy)
1.
Remove the Middle Housing. (p.88)
2.
Remove the Printhead. (p.92)
3. Remove the screw, disengage the hook and remove the Tube Stopper.
(See Figure 4-23)
4. Disengage the hooks (x5) of the Right and Left I/C Holder Assy from the printer
frame.
5. Unhook and remove the Spacer to release the Joint Clamp and disconnect the ink tubes
from the Left I/C Holder.
6. Disconnect the Ink Tube Assy from the Right I/C Holder.
7. Remove the Tube Guide Ground Plate.
(Continued to next page)
Figure 4-23. Disconnecting the Tubes
Figure 4-24. Removing the Valve Assy
C A U T I O N
Take due care not to stain any surrounding objects with ink.
The ink tubes are very delicate. Take due care not to bend or
whiten them by applying undue force.
C A U T I O N
The Joint Clamp, Spacer, Ink Joints (Black) x3, and Pressure
Tube (White) are likely to be damaged once they are removed.
Therefore, do not reuse them, but be sure to replace them with new
ones.
Joint Clamp
Ink Joint (Black)x3
Pressure Tube (White)
Spacer
~Rear Side~
Hooks (x3)
Hooks (x2)
Tube Stopper
Remove the Spacer and
detach the Tube Joints
Disconnect the tubes
Right I/C Holder Assy
Ink Tube Assy
Shank
(right and left)
ValveUnit_Re02.eps
Tube Stopper
Valve Assy

Table of Contents