EasyManua.ls Logo

Epson T-B Series - Standard I;O Connector; Input Circuit

Epson T-B Series
184 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
T3-B T6-B Manipulator 12. Standard I/O Connector
110 T-B series Rev.1
12. Standard I/O Connector
CAUTION
Be careful not to exceed rated current range or rated current which are defined
in manual.
If exceeding rated current, the Manipulator may now operate at worst.
Standard I/O Connector is a connector mounted on back side of the Manipulator for
connecting your input/output equipment to the system.
Connector name
Pins
Bit number
I/O (Input) Connector
18
0-17
I/O (Output) Connector
12
0-11
For cable wiring, refer to “3.7.2 Noise Countermeasures” in order to prevent noise.
Remote function is initially assigned to both input and output from 0 to 8. For further details,
refer to “14. I/O Remote Settings”.
Also, for details of hand I/O, refer to “13.Hand I/O Connector”.
12.1 Input Circuit
Input Voltage Range : +12 to 24 V ±10%
ON Voltage : +10.8 V (min.)
OFF Voltage : +5 V (max.)
Input Current : 10 mA (TYP) at +24 V input
Two types of wiring are available for use with the two-way photo coupler in the input circuit.

Table of Contents

Other manuals for Epson T-B Series

Related product manuals