AT Commands Phone Terminal Terminated 74
Test command: AT*ECAM=? Shows if the command is supported.
Test command
response:
*ECAM: (list of supported <onoff>s)
Parameters:
<onoff>:
<onoff> Description
0 The call log function is disabled
1 The call log function is enabled
<ccid>:
<ccid> Description
1-7 A number that uniquely identifies a call in the phone. The
maximum number of call control processes is 7:
5 multiparty members, one call on hold and one waiting call
<ccstatus>:
<ccstatus> Description
0 IDLE
1 CALLING
2 CONNECTING
3 ACTIVE
4 HOLD
5 WAITING
6 ALERTING
7 BUSY
<calltype>:
<calltype> Description
1 VOICE
2 DATA
4 FAX
128 VOICE2
<processid>: Integer; reported when returning to IDLE state (<ccstatus>=0)
<processid> Description
8=H´08 CC (Call Control)
68=H´44 MM (Mobile Management)
69=H´45 MS (Mobile Station)
122=H´7A RR (Radio Resources)
<exit_cause>: Integer; reported when returning to IDLE state (<ccstatus>=’0’.
<number>: Integer string; Phone number. Format specified by <type>.
Only valid for <ccstatus>=1 (CALLING).