Corrective Maintenance
Fox Maintenance © Essemtec AG 5-11
0000074/05
/ March 31,
2017
Loosen Silicon Tubes
To get access to the feedthrough, it is necessary
to loosen the silicon tube from its metal
connecting piece and to pull down the
connecting piece.
Loosen the grub screw on front of the head (1)
Plug out the silicon tube and pull down the
metal connecting piece (2).
Clean the Axis below the Feedthrough
Clean dust, using IPA Isopropyl alcohol and a
soft lint-free cloth (5).