Page - 122 Revision 2.2 MASTER CLOCK
4.4.4.4.5. Enabling On-Screen Burn in for the Analog Video Test Generator
OUTPUT
This menu item controls whether the on-screen timecode burn in window
will be placed at the bottom of the analog test generator output image. This
burn in window is useful for tagging each frame with a unique timecode ID.
The timecode numbers replace image data hence they are “burned-in” to
the picture.
Note that ena
bling the burn in window does not insert any VITC into the
analog test generator output.
ATG 1
TC Burn in
Off
On
4.4.4.4.6. Enabling Burn in Timecode Dropframe counting for the Analog Video Test Generator
OUTPUT
This menu item allows the user to control whether the dropframe counting
mode will be used for the burn in timecode clock.
This menu item is only applicable to the NTSC image format.
ATG 1
Dropframe Ctl
Off
On
4.4.4.4.7. Enabling Burn in Timecode Colorframe Alignment for Analog Video Test Generator
OUTPUT
This menu enables or disables color frame alignment of the burn-in
timecode clock to the analog test generator output video.
When turned on, the timecode that is burned into the picture will be adjusted
to maintain a correlation to the color field it is inserted on according to
SMPTE ST 12-1 (see section 2.3.4.2 for more detail).
ATG 1
Color Frame
Off
On
4.4.4.4.8. Selecting When the Burn in Time is Synchronized to the System Time
OUTPUT
This menu item allows the user to set the time of day when the analog video
test generator
burn in timecode on the SCI output will be synchronized to
the system time. This synchronization is necessary once per day to maintain
a long-term correlation between the analog video test generator burn in time
and system time for the NTSC image format.
When the time reference is set to GPS, the analog video test generator burn
in time will have to be synchronized to the system time to correct for leap
seconds.
Enter the hour and minute with the and
buttons or by turning the
control knob.
The TG/VI
TC/LTC can also be synchronized to system time immediately
using the Jam Output menu item (see section 4.4.2.2.6). All LTC, VITC and
burn in timecode
outputs can be synchronized to system time in one shot
using the Jam all VitcLtc menu item (see section 4.4.2.2.7).