Model 5601MSC
Model 5601MSC Master SPG/Master Clock System
MASTER CLOCK Revision 2.2 Page - 147
4.5.10.10. Setting the DST Offset
This menu item allows the user to set the amount of adjustment to be made
when DST is active.
Setting the DST offset to 0hrs effectively disables daylight saving time.
1 hour
4.5.11. Saving and Recalling Presets
The 5601MSC allows saving the entire system setup, including all menu settings to a preset. There are
three user presets available, and two factory presets. The Presets menu in the GENERAL root menu
contains controls for saving and recalling user presets, and recalling factory presets.
4.5.11.1. Recalling a User Defined Preset
There are three user-defined presets that can be saved in the 5601MSC.
These are recalled using the Get preset 1, Get preset 2, and Get preset 3
menu items. To recall a user preset, press SELECT on the desired menu
item. The Left LCD screen will briefly display “Are you sure?”. Press the
SELECT button again and the left LCD screen will display “Very sure?”.
Press SELECT a third time to load the preset.
Caution: Lo
ading a preset will immediately apply the user preset
configuration to the 5601MSC. This can cause a large disruption to all
outputs. Perform a user preset recall only when it is safe to do so.
Are you sure?
4.5.11.2. Recalling a Factory Preset
There are two factory-defined presets that cannot be changed by the user.
These are recalled using the Get preset USA, and Get pre EUROPE
menu items. The USA
preset sets all output standards to NTSC,
525i/59.94, or 1080i/59.94, enables global pedestal, and sets the AES
lock mode to NTSC. The EUROPE
preset sets all output standards to
PAL-B, 625i/50, or 1080i/50 and sets the AES lock mode to PAL.
Recalling a factory preset will reset all settings in the unit to their defaults
with the exception of the CONTROL Ethernet port IP settings, Engineering
menu password, SNMP settings, and the NumberPS menu item.
To recall a factory preset, press SELECT on the desired menu item. The
Left LCD screen will briefly display “Are you sure?”. Press the SELECT
button again and the left LCD screen will display “Very sure?”. Press
SELECT a third time to load the preset. Press ESC at any time to abort.
Caution: Loading a preset will immediately apply the factory settings to
the 5601MSC. This can cause a large disruption to all outputs. Perform a
factory preset recall only when it is safe to do so.
Are you sure?