Model 5601MSC
Model 5601MSC Master SPG/Master Clock System
MASTER CLOCK Revision 2.2 Page - 139
4.5.9.3.3. Configuring the SNMP Trap Destinations
GENERAL
There are four trap destinations that the 5601MSC can send SNMP
traps to. Each trap destination has a control menu item, and an IP
address menu item. For sake of simplicity only the menu items for Trap
Destination 1 are shown in the manual.
The Trap 1 Ctl menu item is used to disable or enable sending traps to
the IP address entered for the Trap1 IP Add menu item. When set to
Trap IP disabld
, the unit will not send traps to the Trap 1 IP address.
When set to Trap IP enabled
, an SNMP trap packet will be sent to the
Trap 1 IP address for each SNMP trap event that has been enabled.
The Trap1 IP Add
menu item is used to specify the IP address that the
SNMP traps will be directed to. To log trap events, set this to the IP
address of the computer that is running VistaLINK
®
Pro Serv
er, or
another 3
rd
party SNMP trap logging software.
EngineeringMenu
SNMP
Trap 1 Ctl
Trap 2 Ctl
Trap 3 Ctl
Trap 4 Ctl
Trap IP disabld
Trap IP enabled
Trap1 IP Add
Trap2 IP Add
Trap3 IP Add
Trap4 IP Add
Trap1 IP Add
xxx.xxx.xxx.xxx

Table of Contents