We recommend that you regularly synchronise data at each Xesar access
component to be able to quickly synchronise events with the software (at-
tention: max. 1000 events per access component, after which the oldest
events are overwritten again). If you have installed online components, the
data is updated using XVN (see: 8.15 Xesar virtual network (XVN)) Syn-
chronise each access component at a minimum of once a year to make sure
the time has been synchronised with the system.
Functional principle
Any maintenance tasks or any other tasks for the corresponding Xesar access component are loaded
and logged upon each synchronisation between programming unit and Xesar software.
The connection cable enclosed with your Xesar tablet enables a connection to the Xesar access
component and subsequently represents an option to exchange data using the Xesar app. For more
information read section: 8.14.1 Xesar tablet app
Xesar tablet application (app):
The Xesar application has already been preinstalled on your programming device. A detailed op-
erating manual of the Xesar app for operating your locking system can be found in the chapter
8.14.1 Xesar tablet app
We have enclosed the manufacturer's independent user guide for the Xesar
tablet. It has been enclosed with the product packaging.
Fully charge your Xesar tablet prior to first use!
The app enables the following:
Initialising Xesar access components (first initialisation during commissioning)
Synchronising changed door parameters in Xesar access components
Transferring blacklists to Xesar access components
Checking the battery status (also for third-party systems!)
Checking the current firmware version (also for third-party systems!)
Firmware updates (Xesar access components in battery mode are supplied with energy
from the Xesar tablet during firmware updates)
You can retrieve Xesar access component events
Resetting Xesar access components to construction site mode
Automatically synchronising the time in access components upon communication be-
tween tablet and access components