746 C - 844 C 31 532150 - Rev.A
Translation of the original instructions
ENGLISH
PROGRAMMING MENU
When the display shows the automation status, you
can enter basic or advanced Programming mode.
■ Basic programming
1. Press and hold down the
FF button.
- The first function (
][) is shown on the display and is
displayed as long as F remains pressed.
2. Release the button: the display shows the value
of the function.
3. Press the
++ or
--
button to modify, then press the
FF button to confirm to go to the next function.
Proceed in the same way for all the functions
(see Basic programming menu).
■ Advanced programming
1. Press and hold down the
FF button, then the ++
button as well:
- The first function (
bo) appears on the display,
which is displayed as long as button F remains
pressed.
2. Release the buttons: the display shows the value
of the function.
3. Press the
++ or
--
button to modify, then press the
FF button to confirm to go to the next function.
Proceed in the same way for all the functions
(see Advanced programming menu).
■ Exiting programming mode
i
Every modified value becomes effective immediately,
but when exiting from programming mode you have to
decide whether to save the modifications or not.
Modifications are lost due to TIMEOUT if no buttons have
been pressed for 10 minutes or if power to the board is
disconnected before they have been saved.
1. Press and hold down the
FF button, then the
++
button as well.
- Alternatively, scroll through the programming
menu until you reach the last function (
St).
2. Select:
Y = save the changes
no = DO NOT save the changes
3. Press button
FF to confirm: the display reverts to
the automation status view.
1 Basic programming menu
BASIC FUNCTION Default
][
Simply Connect This code confirms that
Simply Connect is available (default not modifiable).
1
dF
DEFAULT CONFIGURATION
Y the programming corresponds to the DEFAULT
settings
no the programming does not correspond to the
DEFAULT settings
Select
Y if you wish to reload the default values.
Y
Ct
Two-leaf automation Configure the board as
Primary or Secondary.
Pr = Primary
SE = Secondary
Pr
i
The Secondary board does NOT display the settings
reserved for the Primary board:
LO, PA, Pb, bu, tl, PF, Ph, oP, IP, o1, p1, t1,
o2, p2, t2.
LO
OPERATING LOGICS
EP
E
Semi-automatic
EP Semi-automatic step-by-
step
A Automatic
AP Automatic step-by-step
S Automatic Safety
b Semi-automatic B
C Dead man
bC Mixed (b during opening, C
during closing)
Ar Automatic with early
closing
A1 Automatic 1
SP Automatic step-by-step
safety
PA
PAUSE TIME Displayed only if an automatic logic
has been selected.
00…59 Adjustment step: 1 s
1.0…9.5 Adjustment step: 10 s
30
Pb
PARTIAL PAUSE TIME Displayed only if an auto-
matic logic has been selected. It is carried out after
partial opening.
00…59 Adjustment step: 1 s
1.0…9.5 Adjustment step: 10 s
30
F0
MAXIMUM MOTOR FORCE
01…50 (levels)
20
dl
DIRECTION OF TRAVEL Opening direction of the
leaf, established by looking at the gearmotor from
the release device side.
-3 = opens towards the right
E- = opens towards the left
-3
So
OPENING SPEED
01…10 (levels)
10
Sc
CLOSING SPEED
01…10 (levels)
10