746 C - 844 C 48 532150 - Rev.A
Translation of the original instructions
ENGLISH
FIRMWARE VERSION
The firmware version of the board (e.g. 1.0) is shown
on the display each time it is switched on, before the
automation status is shown.
STATUS OF THE AUTOMATION
When the board is not in the programming menus, the
display indicates the automation status with a code.
00
closed
05
opening
01
open
06
closing
02
stationary then opens
09
pre-flashing then opens
03
stationary then closes
10
pre-flashing then closes
04
paused
S0
(flashing)
setup required
WARNINGS FROM A PROGRAMMABLE OUTPUT
The available warnings can be enabled via program-
mable outputs (OUT1, OUT2) (see advanced Program-
ming, functions
o1, o2).
DISPLAYING ERROR CODES, ALARMS
When LED DL5 is lit and the display indicates the
automation status (when not in the programming
menus), it is possible to check the active ERRORS and/
or ALARMS:
- press and hold
++ and
--
simultaneously
The display shows the active errors/alarms, single (e.g.
Er 07) or multiple (e.g. Er 07 Er 16 AL 51).
Refer to table Errors, Alarms.
6 Errors, Alarms
Error (number on white background) - Alarm (number on grey
background).
00
No notification
SL
Radio mode present SLH, SLH LR, LC, RC, DS
Fd
Radio mode present FDS
07
Motor 1 fault Motor disconnected or short-circui-
ted. Check the wiring. If the problem
persists, replace the motor.
09
Mains power supply
fault
Power supply input voltage synchro-
nism problem. Check the mains
power supply.
13
Radio blocked The current radio codes are not com-
patible with the installed radio modu-
le. Clear the radio controls, or change
the radio module type.
The module has been removed or is
damaged.
14
Local radio control
disabled
The radio controls can only be mana-
ged via Simply Connect.
15
SETUP inhibited Make sure that the STOP contact is
not open.
16
Encoder failure Make sure that the encoder is con-
nected properly. If the problem
persists, replace the encoder.
20
Failsafe test failed Device Failsafe test failed. Check
the connections, programming, and
that the safety devices are working
correctly.
22
Programming data
corrupted
Programming data NOT valid or cor-
rupted. If the error persists, resto-
re the default programming and
program again.
24
Consecutive obstacles
in closing
The number of consecutive obstacles
in closing has been reached. Remove
the obstacle. If the problem persists,
repeat the setup.
If the board uses AUTOMATIC logic,
the automation remains open and an
OPEN command is required to close it.
31
Consecutive obstacles
in opening
The number of consecutive obstacles
in opening has been reached. Remove
the obstacle. If the problem persists,
repeat the setup.
32
Motion timeout The movement is in timeout. Check
the manual release or damage to the
rack and pinion gear.
Make sure that the limit switches acti-
vate correctly. If the problem persists,
replace the board or motor.