746 C - 844 C 49 532150 - Rev.A
Translation of the original instructions
ENGLISH
34
Consecutive obstacles
- UL standard
2 consecutive obstacles in opening/
closing were detected. Remove the
obstacle and press the STOP command.
35
Bus 2Easy device
fault/conflict
Check the addresses of the devices.
36
Bus 2Easy short circu-
it / overload
Check the connections of the Bus 2Easy
devices that are connected and re-
gistered.
In the case of a two-leaf automation,
make sure that the Secondary board
has been configured.
39
Setup incorrect or
missing
Perform the setup.
42
Partial open Automation is in partial open mode.
51
Obstacle detected
when closing
Make sure that the NC sensitive edge
terminals are connected or brid-
ged. Make sure that the sensitive
edges are programmed correctly. The
notification disappears on the next
movement.
52
Obstacle detected
when opening
Make sure that the NC sensitive edge
terminals are connected or brid-
ged. Make sure that the sensitive
edges are programmed correctly. The
notification disappears on the next
movement.
53
Number of cycles cor-
rupted
Carry out the scheduled maintenance
of the system.
60
Maintenance request Carry out scheduled maintenance.
65
Setup in progress The setup is in progress. The notifi-
cation remains as long as the phase
is in progress.
76
Radio code memory
full
The radio memory is full.
Simply Connect allows you to delete
any unused radio codes. Use and
additional MiniDec/DECODER/RP
module if necessary.
87
Bus 2Easy registration
in progress
The registration procedure is in pro-
gress.
89
Sensitive edge read
error
Sensitive edges Failsafe test fai-
led. Check the connections, program-
ming, and make sure that the devices
are working correctly.
90
Programming in pro-
gress
The registration procedure is in pro-
gress via Simply Connect.
99
Control board data
deletion
All the data on E781 has been deleted.