746 C - 844 C 29 532150 - Rev.A
Translation of the original instructions
ENGLISH
Carry out the following operations referring to the
§ specific sections.
i
In the case of TWO-LEAF AUTOMATION, before starting,
you have to power the Secondary board to set the
parameter
Ct=SE in basic programming (section §
Two-leaf automation).
1. Turn the power supply on and check the status of
the LEDs (section § Diagnostics).
2. Specify the direction of movement.
3. Install the limit switches on the rack.
4. Perform the setup.
5. Complete the programming.
6. Memorise the radio controls (if used) and put the
automation into service.
6.1 TURNING ON THE POWER SUPPLY
Turn the power supply on.
LEDs DL11 and DL12light up. The display shows:
- 2 alternating dots for 10 s, then the FW version (e.g.
1.0) and then S0 flashing (setup required) or, if the
setup has already been carried out, the automation
status (e.g.
01).
6.2 SPECIFY THE DIRECTION OF
MOVEMENT
1. Go to the dl function in basic Programming and
specify the direction of travel, looking at the gear-
motor from the release device side:
dl = -3 open towards the right
dl = E- open towards the left
2. Then make sure that the direction of movement
is correct using function (
M1). Use buttons ++ and
--
in dead man mode:
++ to OPEN (the display shows oP)
--
to CLOSE (the display shows cL)
If the direction of movement is incorrect, reverse the
phases of the motor (to be done with the power supply
disconnected).
6.3 INSTALLING THE LIMIT SWITCHES
Refer to 20.
i
The two limit switches are marked with different
symbols: SQUARE=closing, CIRCLE=opening.
1. Assemble the limit switches. Insert the spacer
(A) (if necessary) as indicated according to the
thickness of the rack.
2. Release the gearmotor and open the leaf manually
in order to install the opening limit switch. Posi-
tion the OPENING limit switch at the end of the rack
6. STARTUP
as indicated, according to the opening direction of
the leaf. Slide the limit switch along the rack in
the opening direction until the corresponding LED
on the board turns off. Slide the limit switch along
the rack for another 4 cm.
3. Fasten using the 4 screws provided (B, then C).
4. Carry out the same procedure and install the
CLOSING limit switch. Close the leaf manually
and position the closing limit switch at the end
of the rack as indicated in the figure, according to
the opening direction of the leaf. Slide the limit
switch along the rack in the closing direction until
the corresponding LED on the board turns off. Sli-
de the limit switch along the rack for another 4
cm. Fasten using the 4 screws provided (B, then C).
At the end of the procedure, restore gearmotor