BASIC FUNCTION Default
ro
DECELERATION SPACE DURING OPENING
00…30 (% of the stroke)
30
rc
DECELERATION SPACE DURING CLOSING
00…30 (% of the stroke)
30
dS
DECELERATION SPEED
01 = minimum speed
02 = maximum speed
02
OE
OPENING SENSITIVE EDGE Configures the input
dedicated to the sensitive edges that are active
during opening.
nc = 1 sensitive edge with NC contact*
1r = 1 resistive sensitive edge 8.2 k
2r = 2 resistive sensitive edges 8.2 k
3r = 3 resistive sensitive edges 8.2 k
4r = 4 resistive sensitive edges 8.2 k
* Sensitive edges XT S 868 - XR S 868 allow you
to enable the Failsafe (function
3F in advanced
programming)
nc
CE
CLOSING SENSITIVE EDGE Configures the input
dedicated to the sensitive edges that are active
during closing.
nc = 1 sensitive edge with NC contact*
1r = 1 resistive sensitive edge 8.2 k
2r = 2 resistive sensitive edges 8.2 k
3r = 3 resistive sensitive edges 8.2 k
4r = 4 resistive sensitive edges 8.2 k
* Sensitive edges XT S 868 - XR S 868 allow you
to enable the Failsafe (function
3F in advanced
programming)
nc
bu
Learn BUS 2easy devices
See the relative section.
no
M1
DEAD-MAN OPERATION Use the following
buttons to:
++ OPEN (displaying oP)
--
CLOSE (displaying cL)
M1
tL
SETUP See the relative section.
tL
St
LEAVING THE PROGRAMMING MODE
Y exit saving the settings
no exit without saving the settings
After having confirmed using button
FF, the display
indicates the STATUS of the automation:
Y
00
closed
01 open
02 stationary then opens
03 stationary then closes
04 in pause
05 opening
06 closing
09 pre-flashing and then opens
10 pre-flashing and then closes
S0 (flashing)
SETUP required
2 Advanced programming menu
ADVANCED FUNCTION Default
bo
MAXIMUM TORQUE AT INITIAL THRUST
When it starts, the motor operates at maximum
power for 1 s.
Y = enabled, no = not enabled
Y
Sr
SLOW MOVEMENT EACH TIME POWER IS TURNED
ON / RESTORED
Y = enabled, no = not enabled
Y
PF
PRE-FLASHING OF 5 S ON THE LAMP OUTPUT
no = not enabled
oP = enabled before opening
CL = enabled before closing
OC = enabled before opening and closing
no
Ph
CLOSING PHOTOCELLS Specifies the operation of
the closing photocells.
no = reopen immediately
Y = reopen when the photocells are released
no
oP
OPENING PHOTOCELLS Specifies the operation of
the opening photocells.
no = stop with reopening when the photocells
are released
Y = close again immediately
no
EC
ANTI-CRUSHING SENSITIVITY (ENCODER)
00 = anti-crushing not enabled
01 = (minimum sensitivity)
02 =(medium sensitivity)
03 = (maximum sensitivity)
01
rA
LIMIT SWITCH OVERRUN
00…08 in steps of 1 revolution of the motor.
00
IP
REVERSE ON OBSTACLE (from encoder or sensitive
edge)
Y = Partial reverse, no = Total reverse
Y
PO
PARTIAL OPENING WIDTH
10…50 (% of the stroke, in steps of 1 %)
30
1F
FAILSAFE ON PHOTOCELLS
00 = not enabled
01 = enabled on FSW OP input
02 = enabled on FSW CL input
03 enabled on FSW OP and FSW CL input
00
2F
FAILSAFE ON STOP
00 = not enabled
01 = enabled on STOP input
00