EasyManua.ls Logo

FAAC 746 C - Setup Procedure; Configuring Movements and Timing

FAAC 746 C
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
746 C - 844 C 34 532150 - Rev.A
Translation of the original instructions
ENGLISH
6.4 SETUP
The setup procedure consists of a series of movements
during which the board acquires the stroke and other
operating parameters. The setup procedure also regi-
sters the Bus 2Easy devices that are present.
Setup needs to be carried out:
- when
S0 flashes on the display (e.g. when the
automation is first put into operation or after the
board has been replaced)
- if you wish to modify the stroke
Checks prior to setup:
- the automation must not be set to manual mode
- the STOP input must be closed (connected or
bridged)
- In the case of a two-leaf automation, the Secondary
board has to be configured before carrying out the
setup, then the setup procedure will take place
simultaneously on both leaves.
Perform the setup:
1. Go to the
M1 function in Basic programming. Press
the ++ or
--
button to move the leaf so that it is
about 50 cm from the closing limit switch.
2. Press the button
FF to go to the next function tL.
3. Press the
++ and
--
buttons at the same time for
at least 3 s. Release the buttons when
tL starts
to flash.
4. The setup procedure starts and is carried out au-
tomatically. The display indicates each phase in
progress with a flashing code:
S1
The gate closes slowly as far as the CLOSING limit switch
S2
the gate remains stationary for 5 s against the closing limit
switch
S3
the gate opens slowly as far as the OPENING limit switch
01 or 04 (automation status, according to the operating logic)
the setup is finished
i
It is only possible to interrupt the setup procedure by
using the STOP.
If the setup doesn’t start or is not completed,
S0 will
flash again on the display. Before repeating the setup
procedure, resolve any ERRORS there may be (section
§ Diagnostics).
6.5 CONFIGURING MOVEMENTS AND
TIMING
In BASIC Programming
-
Ct Two-leaf automation For this type of installation,
one board must be configured as the Primary and the
other as the Secondary.
-
PA OPEN A pause time, Pb OPEN B pause time In ope-
rating logics with automatic closing, the gate remains
open for the pause time set for total or partial opening.
In ADVANCED programming
-
bo Maximum force at initial thrust If there is par-
ticularly high friction, this allows the maximum force
of the motor to be used when it starts, ignoring the
maximum force limits set in basic programming (
F0).
-
Ph Pre-flashing (5 s) Allows you to enable pre-
flashing before each movement.
-
rA Limit switch overrun Allows you to continue
at a slower speed, after reaching the limit switch (if
necessary to complete the opening/closing).
-
PO Partial opening width Regulates the opening
stroke from the OPEN B command (active in automatic
logics).

Table of Contents

Related product manuals