EasyManua.ls Logo

FAAC 746 C - Page 35

FAAC 746 C
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
746 C - 844 C 33 532150 - Rev.A
Translation of the original instructions
ENGLISH
ADVANCED FUNCTION Default
3F
FAILSAFE ON SENSITIVE EDGES WITH NC CONTACT
and TEST INPUT
00 = not enabled
01 = enabled on EDOP input
02 = enabled on EDCL input
03 = enabled on EDOP and EDCL inputs
00
o1
OUT1 The output is activated according to the
selected function; any timing is set in
t1.
00
00
= Not enabled
01 = Failsafe
02 = Indicator light
03 = Courtesy Light (timed)
04 = Error in progress
05 = Status OPEN/ PAUSE
06 = Status CLOSED
07 = Status MOVING
09 = Status OPENING
10 = Status CLOSING
11 = Opening and closing electric
lock
12 = Safety active
13 = TRAFFIC LIGHT function
(active during OPENING and
with automation OPEN)
14 = Timed output that can be
activated by the second radio
channel XF FDS or XF
15 = Timed output that can be
activated by the second radio
channel XF FDS or XF in step-
by-step mode
33 = Programming in progress
from Simply Connect
P1
OUTPUT POLARITY OUT1
Y = normally closed
no = normally open
NOTE: if the function of the output is Failsafe, the
polarity must be =
no
no
t1
TIMING OUT1
Displayed if
o1 = 03 or 14.
Sets the activation duration of output OUT1, if a timed
function is programmed.
0199 Adjustment in steps of 1 minute.
02
o2
OUT2 The output is activated according to the
function selected (see
o1).
Any timing is set in
t2.
02
P2
OUTPUT POLARITY OUT2
Y = normally closed
no = normally open
NOTE: the Failsafe output requires polarity =
no.
no
t2
TIMING OUT2
Displayed if
o2 = 03 or 14.
Sets the activation duration of output OUT2, if a timed
function is programmed.
0199 Adjustment in steps of 1 minute.
02
AS
MAINTENANCE REQUEST Enables/disables the
maintenance alert when the programmed number of
cycles has been reached as specified in the following
functions (
nb, nc, nd).
no = not enabled, Y = enabled
no
ADVANCED FUNCTION Default
nb
HUNDREDS OF THOUSANDS OF CYCLES Displays
the hundreds of thousands of cycles that have been
performed.
0099 (programmable if AS = Y)
00
nc
THOUSANDS OF CYCLES Displays the thousands of
cycles that have been performed.
0099 (programmable if AS = Y)
00
nd
TENS OF CYCLES Displays the tens of cycles that
have been performed.
0099 (programmable if AS = Y)
To reset the cycle counters
nb, nc, nd: press ++
and
--
for 5 s.
00
St
LEAVING THE PROGRAMMING MODE
(see
St in basic programming)

Table of Contents

Related product manuals