746 C - 844 C 52 532150 - Rev.A
Translation of the original instructions
ENGLISH
11.2 RESTORE FACTORY SETTINGS
The procedure:
- restores all the default programming settings of
the board
- deletes the setup
- deletes all the radio controls
- resets the cycle counter
1. Start with the board not powered, then switch on
the mains power: the display lights up.
2. 2 alternating dots appear on the display for 10 s,
then the FW version is shown (e.g.
1.0). While the
display is showing the FW version, press and hold
down the
++,
--
, FF buttons for approximately 5 s.
The board restarts. Release the buttons when the
alternating dots appear on the display.
At the end of the procedure,
S0 flashes on the display:
the setup procedure has to be carried out.
11.3 PROGRAMMING THE SCHEDULE
MAINTENANCE REQUEST
It is possible to program the number of cycles after
which the maintenance request is displayed: when
the automation reaches the set number of cycles,
there is a pre-flashing of at least 8 s at each movement.
The user should ask the installer to carry out scheduled
maintenance.
1. In advanced programming, function
AS, se-
lect
Y to enable the maintenance request.
2. In function
nb set the value in hundreds using
the
++ and
--
buttons.
3. In function
nc set the value in thousands using
the
++ and
--
buttons.
4. In function
nd set the value in tens using the ++
and
--
buttons.
5. Exit and save the programming.
11.4 CYCLE COUNTER
READING THE CYCLES PERFORMED COUNTER
Add together the readings of functions
nb (hundreds
of thousands),
nc (thousands) and nd (tens) in
advanced programming.
RESETTING THE CYCLE COUNTER
In advanced programming, with function
A S
=
no, go to function nd and press ++ and
--
for 5 s.