746 C - 844 C 24 532150 - Rev.A
Translation of the original instructions
ENGLISH
5.2 REMOVING THE COVER FROM THE
BOARD
The board cover only has to be removed in order
to work on electrical connections or to replace a
fuse. Programming must be carried out with the
board cover installed.
1. Remove the fastening screws (A).
2. Remove the cover (B).
5
B
A
A
5.3 CONNECTIONS
i
When inserting connectors and pull out terminal-boards,
be careful not to bend the printed circuit so as not to
damage the board.
CONTROL DEVICES
i
Multiple NO contacts on same input must be connected
in parallel.
Multiple NC contacts on same input must be connected
in series.
Below is a brief explanation of the inputs. The effect a
command has may vary according to the operating logic
and programming functions.
For connecting devices to inputs with Failsafe enabled,
refer to the Accessories Section.
■ Connecting the devices to terminal board J9:
OP-A
OP-B
STOP
-
-
-
FSW OP
FSW CL
1
2
3
4
5
6
7
8
9
10
11
12
IN1
IN2
IN3
IN4
IN5
1 IN1 OPEN A Total motion command
NO contact. Connect a push-button or another type of
pulse generator which, by closing a contact, commands the
total opening of the gate.
2 IN2 OPEN B Motion command determined by the set
operating logic
NO contact. Connect a push-button or another type of
pulse generator which, by closing a contact, commands:
CLOSING (in logics
C, b, bC)
PARTIAL OPENING (in all other logics)
3 IN3
FSW OP Photocells active during opening
NC contact. Connect a photocell or another device that,
by opening the contact during opening, reverses the gate.
i
If the input is not used, bridge it to terminal −.
4 IN4
FSW CL Photocells active during closing
NC contact. Connect a photocell or another device that,
by opening the contact during closing, reverses the gate.
i
If the input is not used, bridge it to terminal −.
5 IN5
STOP Stop command.
NC contact. Connect a push-button or another type of
pulse generator which, by opening a contact, causes the
automation to stop.
i
If the input is not used, bridge it to terminal −.
6
7
8
− Common contacts/ Accessories power supply negative