Connecting the devices to terminal board J10:
J10
DL20
DL21
OP_H
CL_H
EDCL +
EDOP +
EDOP
-
-
EDCL
-
18
19
20
21
22
23
24
IN6
IN7
18 OP_H Forced opening command
NO contact. Connect a non self-latching control
device.
i
The device has to be activated twice within
2.5 s. The gate moves as long as the second
activation is maintained.
20 CL_H
Forced closing command
NO contact. Connect a non self-latching control
device.
i
The device has to be activated twice within
2.5 s. The gate moves as long as the second
activation is maintained.
22 EDCL
Sensitive edges active during closing
Connect a sensitive edge that, when activated during
closing, causes the gate to reverse.
Configure the
CE function input in basic programming,
to connect:
• sensitive edges with NC contact (default)
• resistive sensitive edges 8.2 k (supports a maximum
of 4 resistive edges)
i
If the input is not used, it should be configu-
red as NC and bridged to the − terminal.
24 EDOP
Sensitive edges active during opening
Connect a sensitive edge that, when activated during
opening, causes the gate to reverse.
Configure the
OE function input in basic programming,
to connect:
• sensitive edges with NC contact (default)
• resistive sensitive edges 8.2 k (supports a maximum
of 4 resistive edges)
i
If the input is not used, it should be configu-
red as NC and bridged to the − terminal.
19
21
23
Common contacts/ Accessories power supply negative
ACCESSORIES POWER SUPPLY
J9
24 V
"
500 mA max
+24 V
+24 V
1
2
3
4
5
6
7
8
9
10
11
12
The E781 supplies 24 V" and is short-circuit protected
with a maximum current of 500 mA.
i
The maximum current limit of 500 mA applies to the sum
of all connected accessories, including BUS 2Easy. To
calculate the maximum power consumption, refer to the
instructions of the individual accessories.
6
7
8
Common contacts/ Accessories power supply
negative
9
10
+24V Accessories power supply positive
LIMIT SWITCHES
The magnetic limit switch connector is connected at
the factory to the dedicated quick connector (J14).
J14
BUS 2EASY DEVICES
2EASY
J8
DL1 DL2
i
Do not exceed the maximum load of 500 mA.
If no Bus 2Easy devices are used, leave the terminals free.
For making the connection and assigning addresses,
see the § BUS 2easy devices section.