26
746 C - 844 C 56 532150 - Rev.A
1
2
90°
4
5
90°
3
6
Translation of the original instructions
ENGLISH
13.1 EMERGENCY USE
13.2 MANUAL OPERATION
In order to operate the leaf manually, the gearmotor
has to be released using the lever with key.
RELEASING THE GEARMOTOR
1. Open the lock cover.
2. Insert the key and turn it clockwise by 90°.
3. Open the release lever by 90°.
!
During manual operation, gently guide the leaf the
whole way. Do not push it and let it slide freely.
Do not leave the gearmotor in the released mode: restore
automatic operation after moving it manually.
RESTORING OPERATION
i
Make sure that the gate is closed with the relative limit
switch engaged before turning the power back on and
operating the automation.
4. Close the release lever.
5. Turn the key so that it is vertical and remove it.
6. Close the lock cover.
Move the leaf manually to make sure that the mecha-
nical system meshes correctly.
In emergencies or if there is a fault, turn off the power
supply to the automation. If the leaf can be moved
safely by hand, use the MANUAL OPERATION mode;
otherwise place the automation out of service until it
has been reset/repaired.
In the case of a breakdown, the automation must be
reset/repaired exclusively by the installer/maintenance
technician.